The electrical features of this combline bandpass filter is its ability to pass the wanted frequencies and to reject all other external, unwanted frequencies.
Its higher protection against receiver de-sensitisation makes it suitable for use at congested urban sites. | | | |
The filter is factory tuned to customer specified frequencies, but may be field retuned in the ordered band.
Frequency bands : 400-420; 450-470; 470-500; 500-520 MHz | | |
|
 |
| MODEL NO |
6CL3-50 |
| FREQUENCY RANGE |
400 - 520 MHz |
| IMPEDANCE |
50 ohms |
| VSWR |
1.3:1 |
| PASSBAND |
1 MHz (typical) |
| INSERTION LOSS |
2 db |
| ISOLATION |
80 dB @ ± 5.2 MHz |
| ISOLATION |
95 dB @ ± 9.5 MHz |
| TEMP. RANGE |
-10°C to +60°C |
| FIELD TUNEABLE |
YES |
| PRE-SET/TUNED |
YES |
| TERMINATION |
'N' FEMALE |
| WIDTH |
483 mm |
| DEPTH |
260 mm |
| HEIGHT |
88 mm |
| WEIGHT |
2.5kg |
 |
|
 |
|
 |
| MODEL 6CL3-50 |
 |
| Typical Response Curve |
|